Choose Timestrip PLUS by the evidence your receiving decision requires, then match the threshold, response behavior and exposure scale. Choosing the longest scale or the nearest temperature is not enough. The indicator’s display must support the decision in your approved process.
This guide explains the ascending, liquid-based PLUS family. Food, Complete, Descending, Blood Temp and electronic Timestrip products have different functions and instructions. Browse and purchase through the Timestrip PLUS collection; use this article to evaluate the fit.
What information does PLUS provide?
PLUS is a single-use visual indicator of qualifying warming exposure. Its retained indication can accumulate across separate exposure periods. It supplies neither an excursion timestamp nor a temperature graph. The manufacturer’s PLUS specifications and FAQs explain its response and limits.
Before ordering, distinguish these terms:
| Term | What the buyer needs to establish |
|---|---|
| Threshold / START | The warming condition that initiates the model’s response. |
| STOP | The lower condition that arrests dye movement; do not substitute START for STOP. |
| Printed exposure scale | The display’s readable exposure range and graduations. |
| Active life | How long an activated device remains suitable for its specified use. |
| Shelf life | The usable period before activation, under specified storage conditions. |
| Shipment duration | The journey and handling interval you intend to monitor. |
Compare the models and printed scales
The following standard ThermLogix listings are 100-packs. Model identity was cross-checked against the Timestrip stock-product catalog, revision A0322, current manufacturer information and inspected product images. The marks below describe the pictured scales; confirm the supplied label and lot instructions when ordering. They are not permissible exposure limits for your goods.
| Model and product link | Nominal threshold | Printed exposure marks | Selection limitation |
|---|---|---|---|
| TP058 | −14°C / 6.8°F | 1, 2, 4, 8, 12, 24 hours | Frozen warming screen; not a −18°C storage check. |
| TP077 | 0°C / 32°F | ½, 1, 2, 4, 8, 12 hours | Ascending warming response, not freeze detection. |
| TP065 | 8°C / 46°F | ½, 1, 2, 4, 8 hours | Upper-exposure candidate; no lower-limit record. |
| TP175 | 8°C / 46°F | 1, 2, 4, 8, 12, 24, 48 hours | Longer exposure scale, not longer product stability. |
| TP153 | 10°C / 50°F | ½, 1, 2, 4, 8 hours | Cannot establish an 8°C upper limit. |
| TP176 | 10°C / 50°F | 1, 2, 4, 8, 12, 24, 48 hours | Different threshold from the 8°C models. |
| TP359 | 10°C / 50°F | 1, 2, 3, 4, 5, 6, 7 days | Day-scale exposure; not a general elapsed-time clock. |
| TP217 | 25°C / 77°F | ½, 1, 2, 4, 8, 12 hours | Screening choice requires a product-specific basis. |
| TP136 | 30°C / 86°F | ½, 1, 2, 4, 8, 12 hours | Not proof that every condition below 30°C was acceptable. |
| TP171 | 38°C / 100°F | ½, 1, 2, 4, 8 hours | Not a 30°C model despite inconsistent overview text. |
For TP058, −14°C converts to 6.8°F. Manufacturer materials use different whole-degree Fahrenheit rounding; select using the Celsius specification and confirm the supplied label. TP171 is the 38°C model, and TP153 is 10°C / 50°F; historical URL wording is not a technical specification.
The catalog also identifies TP170 at −20°C / −4°F and TP365 at 20°C / 68°F. Obtain their current model instructions and label artwork before specifying a detailed reading procedure. This table intentionally does not reproduce unverified graduations from inconsistent or non-product imagery.
Preparation is part of model selection
Preparation requirement for every model in the table: use the supplied model-specific activation conditions, cool after activation to its STOP condition, and attach to the intended surface in the specified state. Obtain that instruction revision before approving the device. This comparison is not a substitute for a timed activation procedure.
START and STOP differ because the dye’s melting and solidification behavior differ. The manufacturer instructs activation above the threshold followed immediately by cooling below STOP. A product or carrier card used at that stage must also be suitably cold. “No pre-conditioning” concerns preparation before activation; it does not remove the subsequent cooling step.
Write your packing instruction with the actual STOP temperature, allowed handling interval, conditioning duration and attachment method from the current model instructions. Do not invent one cooling time for the entire family. Check for an already-activated or expired device before use, then record the activation result.
How should a receiving team read the label?
- Match the model and device identifier to the shipment record.
- Confirm activation and inspect whether the device remained in the approved position.
- Read the exposure window against its printed scale, following the model instructions.
- Photograph the display and record when it was read. Additional exposure after unpacking should not be mistaken for transport exposure.
- Apply the written review criteria. Missing, damaged or unreadable devices require an exception record.
A saturated scale cannot tell you how much further exposure occurred. Nor should a receiver assign an exact duration to an ambiguous position between marks without an approved interpretation method.
What does cumulative exposure mean in practice?
Separate qualifying periods can contribute to one retained reading. As a simple arithmetic illustration, 30 minutes plus 45 minutes plus 15 minutes equals 90 minutes. That calculation is not a prediction of a label’s reading under every changing-temperature profile.
Timestrip states ±1°C temperature accuracy and ±15% time accuracy under isothermal conditions; its FAQ describes time calibration at 2°C above the threshold and faster dye travel at substantially higher temperatures. Therefore, do not treat the scale as a perfectly exact stopwatch under an unknown thermal profile.
Does an 8-hour scale mean an eight-hour shipment?
No. The journey can be longer than the accumulated qualifying exposure. A 48-hour model changes the range and graduations available to read; it does not provide a product-specific permission for a 48-hour excursion.
The manufacturer lists active life up to one year and generally a two-year pre-activation shelf life, with the starting basis differing for some formulations. Use the batch expiry and supplied instructions, not a fresh two-year assumption from your purchase date. Published storage guidance is 22°C / 72°F, 20–80% humidity, in a cool, dark setting.
A decision tree based on the record you need
- Need a dated temperature curve, peak, or excursion timing? Evaluate a suitable calibrated logger and data-retention process.
- Need evidence for both a lower and an upper limit? Specify both functions. One ascending PLUS indicator cannot provide them.
- Need a visible cumulative warming screen? Compare the threshold, STOP behavior, scale and response tolerances with your decision criteria.
- Need elapsed time regardless of temperature? Assess an elapsed-time device or process record instead.
- No defensible match? Do not force a stock PLUS model into the application. Document the gap and evaluate another method.
A logger and a visual indicator can serve complementary roles: detailed evidence for the quality team and an accessible receiving prompt. Cost, data access, operator training, calibration, sampling interval and record retention should be evaluated for the actual devices. See the indicator-versus-data-logger comparison.
Common selection questions
Can an 8°C indicator prove that a shipment stayed between 2°C and 8°C?
No. It has one ascending response function, not a continuous measurement of both boundaries. An unchanged display is not evidence of every condition in the package.
Can a 0°C warming indicator detect freezing?
No. Warming to a threshold and cooling below a threshold are different functions. Specify a lower-temperature monitoring method when that risk matters.
Can PLUS identify the peak temperature or exactly when an excursion occurred?
No. Retained dye progress cannot reconstruct a timestamped sequence or temperature maximum.
What information should a buyer provide?
Supply the product or material, required conditions, upper and lower risks, journey duration, packaging, required records, acceptance criteria and expected quantity. Include the responsible technical contact for suitability decisions.
Move from a candidate to an approved model
Use the general temperature-monitoring selection guide if your monitoring method is still undecided. For a defined PLUS application, compare the linked models and request model instructions and volume pricing. Approval should include the operating procedure and evidence requirements, not just the purchase order.